Key takeaways
- NAFS is the North American Fenestration Standard, published jointly as AAMA/WDMA/CSA 101/I.S.2/A440.
- A rating such as AW-PG60 combines a performance class (AW) with a performance grade (PG60) and applies to the tested size and configuration.
- The class and grade a building needs are set by its height, exposure and location, not by the product.
A window quotation arrives with a line that reads "AW-PG60, tested at 900 x 1500 mm". For anyone who does not read test reports every day, here is what that line says and what it does not.
What NAFS is
NAFS stands for the North American Fenestration Standard. Its full designation is AAMA/WDMA/CSA 101/I.S.2/A440, because it is published jointly by three organizations, including the CSA Group. It sets out how windows, doors and skylights are tested and rated for structural strength, water penetration resistance and air leakage.
Canada applies NAFS together with a Canadian Supplement, CSA A440S1. The current supplement, A440S1:25, accompanies the 2022 edition of NAFS. The supplement adapts the standard to Canadian climate data and code requirements. The edition that applies to a project is the one referenced by the building code in force in that province, so confirm it with the project's design professionals.
Performance class
The class describes the kind of building the product is intended for. NAFS defines four:
| Class | Typical use |
|---|---|
| R | One- and two-family dwellings |
| LC | Low-rise and mid-rise multi-family and light commercial |
| CW | Low-rise and mid-rise buildings needing larger sizes and heavier use |
| AW | High-rise and mid-rise buildings, and demanding use or loading conditions |
Higher classes involve additional and more demanding tests, including life-cycle testing of operating hardware for the AW class.
Performance grade
The performance grade, or PG, is tied to the design pressure the product withstood in testing, expressed in pounds per square foot. PG60 corresponds to a design pressure of 60 psf, about 2,880 pascals. To earn the grade, the unit must also pass the associated water penetration and air leakage tests.
Reading a real example
Take a casement window rated AW-PG60 at a tested size of 900 x 1500 mm, with water resistance of 720 Pa and air leakage between 0.10 and 0.22 L/s per square metre at 75 Pa.
- AW tells you the test program was the most demanding of the four classes.
- PG60 tells you the unit resisted a design pressure of 60 psf.
- The tested size tells you the limits of the result. A larger unit of the same series is not automatically covered.
- Water and air figures are reported because they are assessed separately against Canadian requirements.
Matching the rating to the building
The product does not decide what rating is needed; the building does. The design professional determines the required class and grade from the building's height, its exposure, and climatic data for its location, using the Canadian Supplement. A window that is ample for a four-storey building in a sheltered location may be inadequate near the top of a tower.
Thermal performance is a separate question
NAFS does not rate energy performance. U-factor, solar heat gain coefficient and visible transmittance are reported through thermal rating programs and are assessed against the energy code. In Alberta, buildings are designed to the National Building Code, 2023 Alberta Edition, and the National Energy Code of Canada for Buildings 2020. A complete window submittal therefore contains both a NAFS test report and certified thermal ratings for the specified glazing.
What to ask a supplier
- Which product type and size was tested, and by which laboratory?
- Does the tested configuration match what is being supplied, including glazing and hardware?
- What are the certified thermal ratings for the glazing option specified?
- Is the result evaluated to the Canadian Supplement?
Krangard Supply's aluminum windows and glazed doors are laboratory tested to NAFS, with class and grade stated for the tested size and glazing on each product page.
Sources
This article is general information, current as of the date shown. It is not legal, financial, engineering or code-compliance advice. Confirm requirements for your project with qualified professionals and the authority having jurisdiction.
Request a quote