Krangard Group
Loading the next chapter…
Krangard Group
Loading the next chapter…
Krangard Supply
7 product categories and 47 product families, for Canadian projects, quoted from your drawings.

Product categories
Select the categories that match your scope. We coordinate quotations and site delivery against your drawings and schedule.

Nine product lines for the suite interior, supplied as one coordinated package.
9 product families
Thermally broken aluminum windows, glazed doors and fire-rated assemblies for Canadian projects.
10 product families
Cladding, laminate, decorative panels and wallcoverings for public interiors.
View category
Workplace, hospitality, residential and education furniture, with lockers and storage.
9 product families
Wall protection, handrails, grab bars and care-environment bathrooms and furniture.
View category
Monobloc heat pumps, packaged terminal heat pumps and hydronic fan coils.
10 product families
Site furniture, louvred pavilions, garden sheds, greenhouses, storage and fencing.
9 product familiesAll products
47 of 47 product families

Windows, Doors & Envelope
Awning windows in an 81 mm thermally broken aluminum frame, tested to AW-PG50 with NFRC certified thermal ratings.
Specifications

Windows, Doors & Envelope
Outward-opening casement windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified ratings.
Specifications

Windows, Doors & Envelope
Fixed windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified thermal ratings.
Specifications

Windows, Doors & Envelope
Hinged terrace doors in a 91 mm thermally broken aluminum frame, tested to CW-PG40 and 250,000 operating cycles.
Specifications

Windows, Doors & Envelope
Lift-and-slide doors in a 152 mm thermally broken aluminum frame, tested to CW-PG30 at 4550 × 2600 mm.
Specifications

Windows, Doors & Envelope
Sliding patio doors in a 122 mm thermally broken aluminum frame, tested to CW-PG40 at 2438 × 2438 mm.
Specifications

Interior Finishing
Solid-surface bathtubs, basins and shower bases, with toilets, faucets and valves selected to complete each bathroom.
Specifications

Interior Finishing
Reach-in closets, walk-in dressing rooms and built-in wardrobes finished to match the suite's cabinetry and doors.
Specifications

HVAC Systems
Wall monobloc heat pump with published heating capacity and COP at 47, 10, 5 and −5 °F; no outdoor unit. Available from January 2027.
Specifications

Furniture & FF&E
Conference and meeting tables 2000 to 4800 mm long for four to twenty seats, with power in the top, plus flip-top training tables.
Specifications

Furniture & FF&E
Classroom desk and chair sets, lecture-hall rows, auditorium seating and residence furniture for schools and training centres.
Specifications

Furniture & FF&E
Executive and manager desks 1400 to 3500 mm long with matching wall units and credenzas in wood-grain lacquer and melamine.
Specifications

Windows, Doors & Envelope
Exterior insulation system by project specification, offered once its evaluation for Canada (CAN/ULC-S716) is confirmed.
Specifications

Windows, Doors & Envelope
Hollow-metal steel fire doors with frames, listed to CAN/ULC S104 from 20 minutes to 3 hours and delivered labelled.
Specifications

Windows, Doors & Envelope
Mineral-core wood fire doors supplied with matching frames, listed to CAN/ULC S104 and delivered labelled.
Specifications

HVAC Systems
120 mm deep hydronic fan coil for floor-standing or horizontal ceiling installation; 3,033 to 11,533 Btu/h cooling; 3 to 17 W fan.
Specifications

HVAC Systems
Floor-standing monobloc heat pump for narrow floor space, recessed or ducted; 8,500 to 13,600 Btu/h in three cabinets; R32.
Specifications

Outdoor Living
Polycarbonate and glass greenhouses with aluminum frames from 4 × 4 ft to 20 × 8 ft, and raised beds in steel or PVC.
Specifications

HVAC Systems
120 mm deep high-wall hydronic fan coil for chilled and hot-water systems; 4,095 to 8,360 Btu/h cooling; eight fan speeds.
Specifications

Interior Finishing
Lever sets, hinges, latches, sliding systems and smart locks selected with the door, so finish and function are settled once.
Specifications

Interior Finishing
Fourteen interior door designs in film, paint and veneer, supplied as leaf, frame and casing so each opening arrives as a complete set.
Specifications

Interior Finishing
Kitchens, islands and bathroom vanities built to approved shop drawings, in nine door-finish families coordinated across the suite.
Specifications

Interior Finishing
Twelve residential LED fixture types, from flush mounts to exterior wall lights, with LED mirrors to complete the bathroom.
Specifications

Furniture & FF&E
Modular seating, sofas, lounge chairs and occasional tables for receptions, breakout areas and amenity lounges.
Specifications

Outdoor Living
Glass-enclosed aluminum pavilions with motorized louvre roofs, blinds, lighting and air conditioning built in; two footprints.
Specifications

HVAC Systems
Inverter wall-sleeve PTHP that runs to −13 °F, with heat-pump data published to −5 °F; 2.8 to 4.8 kW cooling; R32.
Specifications

Furniture & FF&E
Executive, task, visitor and training chairs in leather, fabric and mesh, with high-back, mid-back and conference versions.
Specifications

Furniture & FF&E
Modular office cabinets 800 and 1200 mm wide in three heights, staff lockers, and enclosed pods for calls and small meetings.
Specifications

Furniture & FF&E
Bench desking, panel workstations and sit-stand desks, 1200 to 1800 mm per seat, with screens, pedestals and cable management.
Specifications

Outdoor Living
Site benches and picnic tables in steel, cast aluminum and stainless with hardwood or composite slats, for plazas, parks and campuses.
Specifications

Outdoor Living
Single, recycling and lobby bins from 25 to 120 litres in galvanized or stainless steel with composite, hardwood, stone or laser-cut panels.
Specifications

Outdoor Living
Planters and planter benches in stainless steel, steel and aluminum, with stainless steel bike racks, in site-wide shared finishes.
Specifications

Outdoor Living
Steel stores for bins, logs, tools and bikes, plus resin cabinets 65 to 225 cm high, to keep a site tidy.
Specifications

HVAC Systems
208 V monobloc heat pump with two front-panel designs; 8,374 Btu/h cooling, 7,839 Btu/h heating, with or without a 2,000 W heater.
Specifications

Windows, Doors & Envelope
Pre-finished interior doors delivered pre-hung in an adjustable frame with hinges and casing, as one set.
Specifications

Outdoor Living
Aluminum privacy fence with 5 × 5 in posts at 96 in centres, resin fence panels, and pop-up canopies from 2 × 2 m to 3 × 6 m.
Specifications

Furniture & FF&E
Sofas, armchairs, beds, dining and occasional pieces for furnished suites, show homes and hotel rooms, as single pieces or room sets.
Specifications

HVAC Systems
Monobloc heat pump with a 160 mm (6.3 in) deep cabinet, in inverter, hybrid and air-purifying versions; R32.
Specifications

HVAC Systems
Wall-sleeve PTHP with a 185 mm deep room-side section and heat-pump data published to −5 °F; 9,300 to 14,500 Btu/h; R454B.
Specifications

Outdoor Living
Louvred pavilions with solar-integrated louvres and energy storage: 2.85 kW (600 × 400 cm) or 1.65 kW (400 × 390 cm).
Specifications

Interior Finishing
Veined, stone-look and solid-colour surfaces for kitchens, vanities and feature counters, supplied as sheet or finished tops cut to drawings.
Specifications

Interior Finishing
SPC rigid-core resilient plank with baseboards, casings and transitions, supplied as one colour-matched system.
Specifications

Furniture & FF&E
Staff, school and change-room lockers by door count, with steel filing, cabinets and mobile shelving, powder coated in any RAL colour.
Specifications

Outdoor Living
Colour-coated steel and weather-resistant resin sheds from 3 × 5 ft to 11 × 13 ft, in gable, pent, skylight and woodgrain-look types.
Specifications

HVAC Systems
Wall-mounted single-package R32 heat pump with no outdoor unit or line set; 7,080 to 11,800 Btu/h cooling in two sizes.
Specifications

HVAC Systems
Wall monobloc heat pump connected to a building water loop instead of outdoor air; 8,500 to 12,100 Btu/h cooling, COP 5.2 to 5.5.
Specifications

Interior Finishing
Made-to-measure shades, blinds and shutters produced to the window schedule and delivered labelled by suite.
Specifications
Next step
The catalogue shows our standard range. Krangard Supply also sources to specification through its manufacturer network.