06 / Monobloc Heat Pumps
208 V monobloc heat pump with two front-panel designs; 8,374 Btu/h cooling, 7,839 Btu/h heating, with or without a 2,000 W heater.


Image 1 of 1
The panel-front monobloc is a monobloc heat pump offered with a choice of two front-panel designs. It is listed with the wall monobloc for general room heating and cooling without an outdoor unit.
One capacity is published on a 208 V / 60 Hz supply: 8,374 Btu/h (2.45 kW) cooling and 7,839 Btu/h (2.30 kW) heat-pump heating, supplied as a standard unit or with a 2,000 W electric heater.
Climate and performance notes
Low-temperature heat-pump data for this line is listed as available on request; it is not one of the three lines with published data down to −5 °F.
| Versions | Standard; with electric heater |
|---|---|
| Supply | 208 V / 60 Hz |
| Cooling | 8,374 Btu/h (2.45 kW) |
| Heating, heat pump | 7,839 Btu/h (2.30 kW) |
| Electric heater | Standard: none. With electric heater: 2,000 W |
| EER / COP | 12.08 Btu/W / 3.57 |
| SEER2 / HSPF2 | 14.35 / 7.6 |
| Size and weight | Standard: 932 × 584 × 245 mm; 47.0 kg. With electric heater: 932 × 584 × 245 mm; 52.0 kg |
| Refrigerant | R32 |
| Low-temperature data | On request |
| Front panel | Two front-panel designs |
|---|---|
| Electric heater | None or 2,000 W |
| Standard or mark | Status |
|---|---|
| CSA C22.2 No. 60335-2-40 (electrical safety; cCSAus, cULus or cETLus mark) | Specified to standard |
| CSA B52 Mechanical Refrigeration Code (A2L refrigerants) | Specified to standard |
| ISPM 15 (wood packaging entering Canada) | Specified to standard |
Status reflects Krangard Supply product literature (krangard-supply-06-hvac_2026). Certification is confirmed model by model: the current certificate, listing or test report for the specified model is issued with the project submittal. Code compliance for a building is determined by the project's design professionals and the authority having jurisdiction.
HVAC Systems brochure, pages 4, 7, 10
Applicable data sheets, test evidence, shop drawings and certification documents are coordinated for the selected model. Availability and any outstanding requirements are confirmed during the project review.

Monobloc Heat Pumps
Wall-mounted single-package R32 heat pump with no outdoor unit or line set; 7,080 to 11,800 Btu/h cooling in two sizes.
Specifications

Monobloc Heat Pumps
Wall monobloc heat pump with published heating capacity and COP at 47, 10, 5 and −5 °F; no outdoor unit. Available from January 2027.
Specifications

Monobloc Heat Pumps
Wall monobloc heat pump connected to a building water loop instead of outdoor air; 8,500 to 12,100 Btu/h cooling, COP 5.2 to 5.5.
Specifications
Next step
Send your drawings or product schedule. We will review the requirements and confirm the next steps for pricing, documentation and samples.