02 / Windows
Outward-opening casement windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified ratings.

Outward-opening casement windows share the 81 mm thermally broken aluminum frame of the series. The complete unit was laboratory tested at 900 × 1500 mm to the North American Fenestration Standard and achieved class and grade AW-PG60.
Hardware comprises friction hinges, multi-point locking and handle or crank operation, with fall-restraint on casements. Operating windows were cycled to AAMA 910, and forced-entry resistance was tested to ASTM F588, Grade 10.
Certified U-factors range from 0.28 to 0.31 Btu/h·ft²·°F with double glazing and 0.21 to 0.26 with triple glazing; SHGC and VT are given per glazing option.
Climate and performance notes
Thermal: polyamide thermal break; certified U-factor 0.21 to 0.26 Btu/h·ft²·°F (1.19 to 1.48 W/m²·K) with triple glazing and 0.28 to 0.31 (1.59 to 1.76 W/m²·K) with double glazing. The ENERGY STAR listing printed in the brochure applies to fixed models only.
| Frame | Extruded aluminium, 81 mm deep, with glass-fibre-reinforced polyamide thermal break |
|---|---|
| Seals | EPDM gaskets; corners mitred, keyed and sealed |
| Glazing | Double or triple units, 24 to 50 mm |
| Hardware | Friction hinges, multi-point locking, handle or crank operation, fall-restraint on casements |
| Opening direction | Outward opening |
| Tested size | 900 × 1500 mm |
| Class and grade | AW-PG60 (NAFS-22) |
| Design pressure | ±2880 Pa (60 psf) |
| Water resistance | 720 Pa (15 psf) |
| Air leakage at 75 Pa | 0.10 to 0.22 L/s·m² |
| Also tested | Operating cycles; forced entry Grade 10 |
| Thermal, double glazing | U 0.28 to 0.31 Btu/h·ft²·°F (1.59 to 1.76 W/m²·K); SHGC and VT per glazing option |
| Thermal, triple glazing | U 0.21 to 0.26 Btu/h·ft²·°F (1.19 to 1.48 W/m²·K); SHGC and VT per glazing option |
| Basis of thermal values | Certified range across glazing options; W/m²·K values are converted from the certified imperial ratings |
| Scope of results | Class and grade apply to the tested size and glazing. The required class and grade for a building are set by its height, exposure and location. |
| Glazing | Double or triple units, 24 to 50 mm, with different coatings |
|---|---|
| Operation | Handle or crank |
| Standard or mark | Status |
|---|---|
| AAMA/WDMA/CSA 101/I.S.2/A440-22 (NAFS-22) with CSA A440S1 | Third-party tested |
| AAMA 910 (operating cycles) | Third-party tested |
| ASTM F588, Grade 10 (forced entry) | Third-party tested |
| NFRC 100, 200 and 500 | Certified or listed |
| CAN/CGSB-12.1 (safety glazing) | Specified to standard |
| CSA A440.4 (installation) | Specified to standard |
Status reflects Krangard Supply product literature (krangard-supply-02-windows-doors-envelope-screen). Certification is confirmed model by model: the current certificate, listing or test report for the specified model is issued with the project submittal. Code compliance for a building is determined by the project's design professionals and the authority having jurisdiction.
Windows, Doors & Envelope brochure, pages 3-7, 15
Applicable data sheets, test evidence, shop drawings and certification documents are coordinated for the selected model. Availability and any outstanding requirements are confirmed during the project review.

Windows
Fixed windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified thermal ratings.
Specifications

Windows
Awning windows in an 81 mm thermally broken aluminum frame, tested to AW-PG50 with NFRC certified thermal ratings.
Specifications

Glazed Doors
Hinged terrace doors in a 91 mm thermally broken aluminum frame, tested to CW-PG40 and 250,000 operating cycles.
Specifications