Fixed windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified thermal ratings.

Fixed windows use an 81 mm deep extruded aluminum frame with a glass-fibre-reinforced polyamide thermal break. The complete unit was laboratory tested at 1500 × 2500 mm to the North American Fenestration Standard and achieved class and grade AW-PG60.
The same frame takes double or triple glazing units from 24 to 50 mm, so glazing can be selected against the energy target of the project. Forty-three glazing options carry certified ratings; ten are published in the catalogue, with U-factors from 0.28 down to 0.14 Btu/h·ft²·°F.
Fixed models in the series are listed with Natural Resources Canada under ENERGY STAR, with Energy Ratings of 29 to 43. The listing is confirmed for the selected glazing at quotation, and the laboratory report for the window type is issued with the submittal.
Climate and performance notes
Thermal: polyamide thermal break; triple glazing options with certified U-factors as low as 0.14 Btu/h·ft²·°F (0.79 W/m²·K) and condensation resistance (CR) ratings of 59 to 82 across the ten published options. Fixed models carry ENERGY STAR Energy Ratings of 29 to 43. Thermal cycling was included in the laboratory test.
| Frame | Extruded aluminium, 81 mm deep, with glass-fibre-reinforced polyamide thermal break |
|---|---|
| Seals | EPDM gaskets; corners mitred, keyed and sealed |
| Glazing | Double or triple units, 24 to 50 mm |
| Tested size | 1500 × 2500 mm |
| Class and grade | AW-PG60 (NAFS-22) |
| Design pressure | ±2880 Pa (60 psf) |
| Water resistance | 720 Pa (15 psf) |
| Air leakage at 75 Pa | 0.02 L/s·m² |
| Also tested | Thermal cycling; forced entry Grade 10 |
| ENERGY STAR Energy Rating | 29 to 43 (fixed models, listed with Natural Resources Canada) |
| Glazing 1: Low-E, argon, clear (2 panes, 26 mm unit) | U 0.28 Btu/h·ft²·°F (1.59 W/m²·K); SHGC 0.32; VT 0.59; CR 68 |
| Glazing 2: Low-E, argon, interior-surface low-E (2 panes, 26 mm unit) | U 0.24 (1.36 W/m²·K); SHGC 0.31; VT 0.54; CR 59 |
| Glazing 3: Solar-control low-E, argon, clear (2 panes, 24 mm unit) | U 0.27 (1.53 W/m²·K); SHGC 0.23; VT 0.55; CR 68 |
| Glazing 4: Laminated outer pane, argon, clear (2 panes, 32 mm unit) | U 0.27 (1.53 W/m²·K); SHGC 0.31; VT 0.57; CR 68 |
| Glazing 5: Two low-E coatings, argon, clear (3 panes, 33 mm unit) | U 0.20 (1.14 W/m²·K); SHGC 0.41; VT 0.61; CR 80 |
| Glazing 6: Two low-E coatings, argon, clear (3 panes, 39 mm unit) | U 0.18 (1.02 W/m²·K); SHGC 0.40; VT 0.60; CR 81 |
| Glazing 7: Two low-E coatings and interior-surface low-E (3 panes, 40 mm unit) | U 0.16 (0.91 W/m²·K); SHGC 0.39; VT 0.55; CR 73 |
| Glazing 8: Two solar-control low-E coatings, clear (3 panes, 42 mm unit) | U 0.16 (0.91 W/m²·K); SHGC 0.18; VT 0.40; CR 82 |
| Glazing 9: Laminated triple (3 panes, 50 mm unit) | U 0.17 (0.97 W/m²·K); SHGC 0.24; VT 0.45; CR 79 |
| Glazing 10: Two solar-control coatings and interior-surface low-E (3 panes, 50 mm unit) | U 0.14 (0.79 W/m²·K); SHGC 0.18; VT 0.42; CR 73 |
| Basis of thermal values | Standard test size, no grids. U-factors are whole-window values in Btu/h·ft²·°F; W/m²·K values are converted from the certified imperial ratings |
| Combination (mulled) window test | Tested at 2720 × 2400 mm to NAFS-17: measured values (no class and grade printed); design pressure ±2880 Pa; water resistance 440 Pa; structural load ±4320 Pa |
| Scope of results | Class and grade apply to the tested size and glazing. The required class and grade for a building are set by its height, exposure and location. |
| Glazing | Double or triple units with different coatings; 43 certified glazing options, ten published |
|---|---|
| Glass types shown | Low-E, solar-control low-E, interior-surface low-E, laminated; argon fill |
| Series | Fixed, awning and casement windows share the 81 mm frame |
| Standard or mark | Status |
|---|---|
| AAMA/WDMA/CSA 101/I.S.2/A440-22 (NAFS-22) with CSA A440S1 | Third-party tested |
| ASTM F588, Grade 10 (forced entry) | Third-party tested |
| NFRC 100, 200 and 500 | Certified or listed |
| ENERGY STAR (Natural Resources Canada listing) | Certified or listed |
| AAMA/WDMA/CSA 101/I.S.2/A440-17 (NAFS-17), combination window | Third-party tested |
| CAN/CGSB-12.1 (safety glazing) | Specified to standard |
| CSA A440.4 (installation) | Specified to standard |
Status reflects Krangard Supply product literature (krangard-supply-02-windows-doors-envelope-screen). Certification is confirmed model by model: the current certificate, listing or test report for the specified model is issued with the project submittal. Code compliance for a building is determined by the project's design professionals and the authority having jurisdiction.
Windows, Doors & Envelope brochure, pages 3-7, 15
Applicable data sheets, test evidence, shop drawings and certification documents are coordinated for the selected model. Availability and any outstanding requirements are confirmed during the project review.

Windows
Awning windows in an 81 mm thermally broken aluminum frame, tested to AW-PG50 with NFRC certified thermal ratings.
Specifications

Windows
Outward-opening casement windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified ratings.
Specifications

Glazed Doors
Sliding patio doors in a 122 mm thermally broken aluminum frame, tested to CW-PG40 at 2438 × 2438 mm.
Specifications
Next step
Send your drawings or product schedule. We will review the requirements and confirm the next steps for pricing, documentation and samples.