02 / Glazed Doors
Sliding patio doors in a 122 mm thermally broken aluminum frame, tested to CW-PG40 at 2438 × 2438 mm.

Sliding doors in thermally broken aluminum serve balconies, terraces and ground-floor suites. The sliding door uses a 122 mm frame and was laboratory tested as a complete unit at 2438 × 2438 mm, achieving class and grade CW-PG40.
Thermal performance with triple glazing, across five options, is a U-factor of 1.35 to 1.63 W/m²·K and SHGC of 0.27 to 0.49. These values are based on simulation to CSA A440.2, with Energy Ratings of 25 to 36.
The sliding door was tested to the 2022 edition of the North American Fenestration Standard with CSA A440S1, including forced entry to Grade 10.
Climate and performance notes
Thermal: thermally broken aluminum frame with triple glazing; U-factor 1.35 to 1.63 W/m²·K and Energy Rating 25 to 36, both from CSA A440.2 simulation. The brochure does not print an NFRC certified rating for the sliding door.
| Frame | Thermally broken aluminium, 122 mm |
|---|---|
| Tested size | 2438 × 2438 mm |
| Class and grade | CW-PG40 (NAFS-22) |
| Design pressure | ±1920 Pa (40 psf) |
| Water resistance | 290 Pa |
| Air leakage at 75 Pa | 0.16 to 0.21 L/s·m² |
| Also tested | Forced entry Grade 10 |
| Thermal, triple glazing (five options) | U 1.35 to 1.63 W/m²·K; SHGC 0.27 to 0.49 |
| Basis of thermal values | CSA A440.2 simulation; Energy Rating 25 to 36 |
| Scope of results | Class and grade apply to the tested size and glazing. The required class and grade for a building are set by its height, exposure and location. |
| Glazing | Triple, five options |
|---|
| Standard or mark | Status |
|---|---|
| AAMA/WDMA/CSA 101/I.S.2/A440-22 (NAFS-22) with CSA A440S1 | Third-party tested |
| CSA A440.2 (thermal simulation) | Specified to standard |
| CAN/CGSB-12.1 (safety glazing) | Specified to standard |
| CSA A440.4 (installation) | Specified to standard |
Status reflects Krangard Supply product literature (krangard-supply-02-windows-doors-envelope-screen). Certification is confirmed model by model: the current certificate, listing or test report for the specified model is issued with the project submittal. Code compliance for a building is determined by the project's design professionals and the authority having jurisdiction.
Windows, Doors & Envelope brochure, pages 7-9, 15
Applicable data sheets, test evidence, shop drawings and certification documents are coordinated for the selected model. Availability and any outstanding requirements are confirmed during the project review.

Glazed Doors
Lift-and-slide doors in a 152 mm thermally broken aluminum frame, tested to CW-PG30 at 4550 × 2600 mm.
Specifications

Glazed Doors
Hinged terrace doors in a 91 mm thermally broken aluminum frame, tested to CW-PG40 and 250,000 operating cycles.
Specifications

Windows
Fixed windows in an 81 mm thermally broken aluminum frame, tested to AW-PG60 with NFRC certified thermal ratings.
Specifications
Next step
Send your drawings or product schedule. We will review the requirements and confirm the next steps for pricing, documentation and samples.